GPS IWV solutions. ================== document prepared by O. Bock Last revision: 26 Jan 2005 ============ IWV data are converted from GPS ZTD (Level 1a), using surface pressure and temperature (Meteo-France surface stations). Contacts: - ZTD Data processing: bouin@ensg.ign.fr - IWV Data processing: Olivier.Bock@aero.jussieu.fr IWV files content: 4 rows: date ZHD IWV SIGMA - date format: yymmdd.hh - ZHD = calculated from Saastamoinen formula and observed surface pressure - IWV = converted from estimated GPS ZTD - SIGMA = converted from ZTD precision (see readme.txt for ZTD files) Units: - ZHD [m] - IWV [kg/m2] - SIGMA [kg/m2] ============== version: v01*.iwv converted from: v01*.ztd